· i have a two family home with a 200 amp panel in each dwelling. · bc hydro spec es53 s1-01 shows the 320a meter base but doesn’t list an applicable model like it does for the 400a, but those specs do show a 320a meter base needing a single 300a customer breaker or 200a/125a in two panels. Service is overhead, and id like to get one of these 2 gang meter setups, but im having some problems. · overhead or underground? · i have a question concerning the 2020 nec changes in 230. 70, 230. 71, specifically 230. 71 (b): · square d makes a 400 amp meter main now that uses a 320a meter socket and has twin 200 amp main breakers on the load side for connecting sub-panels. In case of an emergency or maintenance work, this device allows for quick … · also, if the cable distance is more than 10 feet they will put two 200 amp disconnect boxes next to the meter panel. The new panel cannot be a type which has additional breaker slots fed directly from the utility meter (ie. 200a disconnects each going to 200 amp main lug panels. There are options out there for twin 200 amps with disconnects. · i have always been partial to the square d qo line of panels and meter bases, but i searched the square d on-line catalogue and could not find any 400 amp meter dual feed meter … They are not in stock anywhere. Please update the plans to show a … The state inspector … Usually we spec out siemens or square d meter main with 2-200a main breakers to feed the load panels which are distributed inside the house. · ive installed the service wire from the weather-head down to the top (line) of the meter and then have run the wires (double tapped) from the bottom of the meter (load) out to … · shuts off all other breakers. First and foremost, a 400 amp meter base disconnect allows for easy and safe access to the main electrical panel. · doing the typical 400a nom 320a cont residential service feeding 2-200a main lug panels. Cannot install a “hot bus” service panel anymore per the 2020 cec). Anyone have one they could sell me or … Main issue will be delivery time. · having a real problem finding a 320 or 400 amp meter base for a residential parallel 200amp panel setup. I was thinking there was a 400 amp breaker. I always called them trailer panels- … Prior to 2020 nec, a 400a meter main allowed 2 x 200a main breakers in the same … Here’s a 320/400 setup with the exterior disconnects in seperate … Very similar to the 200 amp meter/mains, just has 2 breakers instead of one. · on a recent installation of a single phase 400 amp with standard ringless meter base going to two. · theres no physical barrier separation between the 200 amp breakers. So the other option is to use a 400 (320) amp meter base and 2- 200 amp feed thru panels. Gutter and two 200 amp meter mains … Outside disconnect is required.
My Electrician Hated This Square D 400 Amp Meter Base With 2 200S Heres Why
· i have a two family home with a 200 amp panel in each dwelling. · bc hydro spec es53 s1-01 shows the 320a meter...